Sep 24, 2026

Top 10 Issues with Sound Masking Specs

Avoid making the most common mistakes

Many acoustical goals and architectural choices depend on assured—rather than assumed—minimum background sound levels following a suitable spectrum, which can only be achieved using a sound masking system. Successful implementation of this technology reduces variability in the sound field due to architecture, as well as perception of intruding noise from various sources,
enhancing occupant productivity, speech privacy, acoustical comfort, and overall well-being.

Given the lack of performance standards governing the masking industry—as well as the widely varying product efficacy and technical training one sees within this field—strong specification is needed to ensure the consistent and verified performance necessary to rely on masking sound as part of a facility’s overall acoustical design strategy. However, few people have in-depth understanding of key requirements, leaving projects at the mercy of incomplete, inconsistent, or even outdated specs.

Here, I talk about the issues I often encounter when reviewing, responding and bidding to sound masking specs, together with examples that recently crossed my desk. By raising awareness of potential pitfalls—which, if not caught, questioned and corrected, can significantly affect outcomes—many more organizations and their employees stand to benefit from properly performing masking sound.


1. Failing to set an effective performance bar

When purchasing a masking system, it’s important to remember the end product isn’t the hardware, but rather the masking sound itself and the acoustical benefits it provides. Outcomes are strongly related to the consistency with which masking sound is delivered, yet specs often fail to include performance targets for spectrum and levels (in some cases, merely calling for “a sound masking system” to be installed), allowing suppliers to proceed without targets to which they could be held accountable. In other words, the primary reason for purchasing the technology—the masking effect—is left to chance. One document I reviewed omitted key masking requirements, but devoted several paragraphs to labelling equipment racks and cabling!

Even when performance requirements are included, they’re frequently too lenient, specifying broad tolerances for level and frequency variation, a spectrum that covers too narrow a range, or control capabilities insufficient to meet stated targets and testing standards. In such cases, masking results can vary significantly—and in unpredictable locations across the client’s space—compromising not only the consistency with which occupants experience speech privacy and noise control, but potentially also their comfort. It may be difficult or even impossible for the supplier to address these problems ‘after the fact,’ particularly if the spec’s control criteria were inadequate. If comfort is negatively impacted because the sound is too loud in areas and/or too hissy or rumbly, the client may have no choice other than to turn the masking off (yes, that happens).

Key takeaway: Set control requirements for the system, including the size of zones permitting one-third octave and level adjustment, as well as tested performance requirements for the masking sound, including the target spectrum, overall level(s), and acceptable tolerances for both.


2. Relying on an old template

Specs are usually templated documents. Using a template as a starting point isn’t necessarily a problem; however, like most technologies, masking systems have significantly evolved over time as new research, standards and technical understanding demanded changes be made in order to continue to improve client outcomes. Specs should keep pace with these developments. However, I continue to see templates circulating that reflect 1970s masking capabilities, and vendors who still manufacture products based on 1970s system architectures. The most conspicuous of these is the centralized system, in which loudspeakers—sometimes as many as hundreds—are grouped into large control zones, providing very little ability to adjust the sound delivered to the client’s facility. The technician simply can’t fine-tune its qualities in the numerous areas in which they’re impacted by the physical attributes of the space (e.g. architecture, fit out, furniture, finishings).

Using a template can lead to further issues. For example, it may include elements (e.g. functional requirements, such as paging & music and/or software control) from a past project that don’t apply to the current one, or even specifier’s notes upon which the issuer should have acted (e.g. adding limits for control zone size) and then deleted. In this case, the spec may not reflect the current client’s needs, and they’re also within their rights to ask the supplier for something that wasn’t contemplated during project meetings or in quotes… but is in the spec. 

Key takeaway: Consistently update a template to reflect the control capabilities of modern masking technologies, as well as the specific requirements of the project at hand.


3. Setting vague, inconsistent, or incompatible requirements

Vaguely worded requirements cause confusion during the procurement process and are impossible to assess post-implementation. For example, while specs calling for “equalization in thin strips,” a “high-fidelity broad band speaker,” or “tune to the spectrum as best as possible” create an impression of requirements, they’re unclear and unenforceable. Rather than holding a supplier to account, at best, they waste time due to the need for clarification and, at worst, open the door to underperforming bids.

Responding to a spec that calls for a particular requirement in one place and a different or completely incompatible one elsewhere is also challenging. Examples I’ve seen include documents outlining two distinct testing methods, and others calling for a spectrum covering 100 to 10,000 Hz to be delivered by a product that only provides control from 200 to 5,000 Hz (and, hence, cannot meet the required output levels). When a spec includes two or even more contradictory requirements, which is correct? To which is the supplier meant to be accountable?

Key takeaway: To avoid confusion, keep requirements clear and consistent.


4. Including ‘thou shalt not’ and promotional statements

Specs declare what is required. Documents that assert something isn’t allowed raise concerns about objectivity and professionalism, as such statements are typically included to limit competition rather than serve the client; for instance, “systems using above-ceiling active electronics are not permitted.”

Similarly, some specs purport to permit competitive bids, but include proprietary details that technically prohibit all but one product from being proposed. Worse still, these proprietary elements are often immaterial to masking performance, such as requiring particular enclosure dimensions. In these cases, one either has to limit bids to one product or basically scrap the spec to let others bid. At times, an attempt to justify the proprietary feature follows; for example, calling for loudspeakers that use a particular mounting mechanism and adding “to minimize installation time in ceiling tiles and enclosures.” This type of content is better suited to a brochure than a spec.

Key takeaway: Say what is required for the project, not what isn’t. It’s also best to stick to the facts and save any editorializing for marketing materials.


5. Using undefined or inconsistent terminology

To communicate effectively and ensure all parties understand one another, it’s necessary to use clear and consistent terminology. Unfortunately, many sound masking specs use terms in different ways throughout the document; for example, using “zone” to refer to a masking control zone, but also to an area in which masking is expected to be at a particular level. Or specifying requirements for a “zone” in one paragraph, but substituting the words “channel,” “area,” “loudspeaker group,” or “device” in others. These kinds of inconsistencies require (or allow) suppliers to interpret what’s meant, creating misunderstandings (or loopholes).

Key takeaway: Define key terms at the outset, and use them consistently throughout the document.


6. Applying inapplicable or outdated standards

Specs sometimes include standards that don’t apply to masking systems or evaluation of their performance, making them irrelevant or impossible to meet. For example, some state the system must comply with ASTM E1374—a purely informational document called Standard Guide for Office Acoustics and Applicable ASTM Standards that doesn’t contain any requirements. At most, this document defines what a masking system is and identifies its basic components. The only way a masking system can ‘comply’ with E1374 is simply by virtue of including those components, just as a “car” complies with the dictionary definition of “a motor vehicle on wheels.”

Including up-to-the-minute references isn’t always possible, but specs shouldn’t refer to ones many years—or even decades—out of date. I continue to see references to ASTM E1041, Standard Guide for Measurement of Masking Sound in Open Offices, which might sound applicable, but was actually withdrawn over twenty years ago. Because such old standards reflected old masking technologies and, hence, were too lax in their requirements, in 2018, ASTM issued an updated, and much more rigorous, standard for measuring masking sound in both open and closed spaces, which it further revised in 2022, resulting in ASTM E1573-22, Standard Test Method for Measurement and Reporting of Masking Sound Levels Using A-Weighted and One-Third-Octave-Band Sound Pressure Levels. Since this current standard exists, why refer to one that’s obsolete?

Key takeaway: Ensure the spec refers to the most current version of relevant standards, such as ASTM E1573.


7. Contradicting referenced standards

At times, specs refer to a standard—suggesting it applies—but then include requirements that don’t comply with it. For instance, some indicate the masking sound should be measured per ASTM E1573-22… but only in the single 2,000 Hz full octave band, and/or using Class 2 sound analyzers, and/or using 4-second measurements, all of which contradict E1573-22. This approach isn’t only confusing, it’s a potentially deceptive practice that could be termed “standards-washing”—similar to “green washing” whereby an organization creates a false impression that their products, goals and/or policies are environmentally friendly.

Key takeaway: Don’t include content that contradicts referenced standards.


8. Pre-approving manufacturers or non-conforming products

Specs often contain a list of approved manufacturers; however, they should list product lines. Why? Because some manufacturers offer a variety of products, some of which may not be capable of meeting spec. For clarity, it’s best to list the specific conforming product(s), with the emphasis on conforming. Listing a series of manufacturers or unvetted products implies they offer a similar level of performance, which is rarely the case as there are significant differences between brand offerings. 

It’s also not uncommon for a spec to name a particular product as the basis of design and then outline requirements it can’t meet; or vice-versa, outline requirements and then list one or more products that can’t meet them. Either causes confusion. Are the requirements null and void… or are the listed products in fact unacceptable?

Key takeaway: Only list conforming products.


9. Incorporating inadequate drawings

Including drawings is good practice, because it helps align competitive bids with respect to system coverage, loudspeaker locations, installation approaches, and control zones. However, if they’re not clear and complete, they can present an obstacle to vendors responding to the specs. For example, a drawing may show loudspeaker locations, but not how they’re grouped into control zones. Or it may show the desired overall level of masking in various areas, which can be (mis)interpreted to be control zones. Vendors can then propose systems with control zones that aren’t able to meet the desired performance in all areas. In other cases, loudspeaker location and spacing are such that it’s impossible to achieve the stated expectations for masking coverage and consistency.

Key takeaway: Include clear and complete drawings.


10. Missing or weak testing requirements

In #1, I talk about the need to set performance requirements for the masking sound, but they’re meaningless if the sound isn’t properly tested post-implementation. Fortunately, ASTM E1573-22 provides a high-quality, industry-accepted measurement method. Unfortunately, many specs either omit this standard, include and then contradict it, or specify other measurement methods insufficient to ensure the sound is consistently providing masking across all treated areas. For example, it’s common to see specs that permit testing using inaccurate (non-Class 1) sound analyzers, overly short measurement periods, or too few measurement locations, as well as those measuring only overall levels, too narrow a frequency range, or in full rather than one-third octave bands—lax requirements that only serve to make life much easier for the supplier. Without an objective assessment using E1573-22 as the basis of conformity and detailed reporting of results, there’s no assurance of compliance. In other words, there’s no evidence the client has actually gotten what they’re paying for: the acoustical effects of masking sound.

Key takeaway: Include testing requirements that meet or exceed the current version of ASTM E1573, and require a detailed report of the results.


Of course, issuing an effective spec is only the first step needed to ensure end users receive a masking system that works. All too often, it’s assumed all bidders will at least conform to its terms, but unless a member of the project team is both able and empowered to enforce them, the results are still anyone’s guess.

Although delivery of masking sound can’t be assessed until after the equipment is installed and the sound is tuned, the appointed team member can carefully review each vendor’s submission to ensure: a) the product(s) they’re offering for consideration can meet the stated control zone requirements, allowing the sound to be adequately tuned to meet final tested (i.e., measured) performance per ASTM E1573-22; b) the vendor has the measurement equipment required by E1573-22 and budgeted sufficient time to perform the testing procedures and adjustments; and c) they’ll provide proof of performance in the form of a detailed written report showing E1573-compliant test results for each control zone. E1573-22 outlines the details required in this report, but it’s also wise to ask for samples of prior project reports from each vendor, to assess their quality. Alternatively, the sound can be independently verified by an acoustical engineer separately contracted by the client.